The InfraSecure System will help to enhance the preventive measures and handle the emergencies in an effective manner, which will minimize - Human, Financial & National Loss.
Wireless Addressable Smoke Cum Heat Detector with Two Way Communication
A | Detector | Wireless Addressable Smoke Cum Heat Detector with Two Way Communication |
1 | Application | For detection of Smoke and Heat |
2 | Voltage range | 3.6 V/ 9VDC(Lithium battery) |
3 | Life of the battery | Minimum 7 years |
4 | Standby current | 20-30μA |
5 | Smoke Sensitivity setting | Field Programmable with Hand-held Device as per the site requirement. |
6 | Thermal setting | 40⁰C -60⁰C with resettable DIP Switch |
7 | Diiff. Alarm Output | Different alarm output for smoke & Temp |
8 | Operating frequency | 433.93 MHz. |
9 | Ambient temperature range | -10deg C to +55deg C |
10 | Wireless Protocol | Two Way Mesh /Multi-hop |
11 | Inbuilt Transreceiver Two Way Communication Module | Mesh/Multi-hop RF Transceiver Module: Frequency bands 433.05 – 433.92MHz Number of channels 10 Data rate 1.2 - 100 Max output power 10 dBm Sensitivity -110 dBm Supply voltage 2.0 – 3.9 Volt Current consumption, RX / TX :24 / 35 mA Current consumption, SLEEP Typ. 0.3 uA Temperature range -40 to +85 Coding : Infinite Programmable at site Modulation :FSK Test Certificate : ERTL |
12 | Individual Data Transmission for |
|
13 | Wireless Protocol | Wireless MESH |
14 | Coverage Area | 25 sq.mtr |
15 | Point Read: Handshaking principle | A: Device status B: Device type C: Custom Device Label D: Software Zone Label E: Device Zone Assignments F: All Program Parameters. |
16 | Handshaking | The Detector shall be in handshaking mode with the respective Hooter panel , Local Monitoring station . Handshaking for health condition to be communicated to the Hooter panel & Local CMS via two way communication with MESH protocol.
Health condition monitoring in each 01 hrx24 hrs of Local Monitoring Station/ Local Hooter Panel so that different Audio visual alarm with graphic presentation of Health condition monitoring of all the devices in Wireless FDA system install in Plant area in fixed intervals. |
Wireless Addressable UV-IR Flame Detector with Two Way Communication
C | Detector | Wireless Addressable UV-IR Flame Detector with Two Way Communication |
1 | Application | For detection of Flame/Spark |
2 | Voltage range | 3.6 V/ 9VDC(Lithium battery) |
3 | Life of the battery | Minimum 5 years |
4 | Standby current | 20-30μA |
5 | Sensitivity setting | Sensitivity adjustment with inbuilt DIP Switch for different sizes of flame |
6 | Sensor | UV_IR |
7 | Alarm Output | Alarm output FOR Diff, sizes of flame |
8 | Operating frequency | 433.93 MHz. |
9 | Ambient temperature range | -10deg C to +55deg C |
10 | Wireless Protocol | Two Way Mesh /Multi-hop |
11 | Inbuilt Transreceiver Two Way Communication Module | Mesh/Multi-hop RF Transceiver Module: Frequency bands 433.05 – 433.92MHz Number of channels 17 Data rate 1.2 - 100 Max output power 10 dBm Sensitivity -110 dBm Supply voltage 2.0 – 3.9 Volt Current consumption, RX / TX :24 / 35 mA Current consumption, SLEEP Typ. 0.3 uA Temperature range -40 to +85 Coding : Infinite Programmable at site Modulation :FSK Test Certificate : ERTL |
12 | Individual Data Transmission for |
|
13 | Wireless Protocol | Wireless MESH |
14 | Point Read: Handshaking principle | A: Device status B: Device type C: Custom Device Label D: Software Zone Label E: Device Zone Assignments F: All Program Parameters. |
15 | Handshaking | The Detector shall be in handshaking mode with the respective Hooter panel , Local Monitoring station . Handshaking for health condition to be communicated to the Hooter panel & Local CMS via two way communication with MESH protocol.
Health condition monitoring in each 01 hrx24 hrs of Local Monitoring Station/ Local Hooter Panel so that different Audio visual alarm with graphic presentation of Health condition monitoring of all the devices in Wireless FDA system install in Plant area in fixed intervals. |
Wireless Addressable IR3 Flame Detector with Two Way Communication
C | Detector | Wireless Addressable IR3 Flame Detector with Two Way Communication |
1 | Application | For detection of Flame/Spark |
2 | Voltage range | 3.6 V/ 9VDC(Lithium battery) |
3 | Life of the battery | Minimum 5 years |
4 | Standby current | 20-30μA |
5 | Sensitivity setting | Sensitivity adjustment with inbuilt DIP Switch for different sizes of flame |
6 | Sensor | IR3 |
7 | Alarm Output | Alarm output FOR Diff, sizes of flame |
8 | Operating frequency | 433.93 MHz. |
9 | Ambient temperature range | -10deg C to +55deg C |
10 | Wireless Protocol | Two Way Mesh /Multi-hop |
11 | Inbuilt Transreceiver Two Way Communication Module | Mesh/Multi-hop RF Transceiver Module: Frequency bands 433.05 – 433.92MHz Number of channels 17 Data rate 1.2 - 100 Max output power 10 dBm Sensitivity -110 dBm Supply voltage 2.0 – 3.9 Volt Current consumption, RX / TX :24 / 35 mA Current consumption, SLEEP Typ. 0.3 uA Temperature range -40 to +85 Coding : Infinite Programmable at site Modulation :FSK Test Certificate : ERTL |
12 | Individual Data Transmission for |
|
13 | Wireless Protocol | Wireless MESH |
14 | Point Read: Handshaking principle | A: Device status B: Device type C: Custom Device Label D: Software Zone Label E: Device Zone Assignments F: All Program Parameters. |
15 | Handshaking | The Detector shall be in handshaking mode with the respective Hooter panel, Local Monitoring station. Handshaking for health condition to be communicated to the Hooter panel & Local CMS via two way communication with MESH protocol.
Health condition monitoring in each 01 hrx24 hrs of Local Monitoring Station/ Local Hooter Panel so that different Audio visual alarm with graphic presentation of Health condition monitoring of all the devices in Wireless FDA system install in Plant area in fixed intervals. |
Wireless Addressable Beam Smoke Detector with Two Way Communication
A | Wireless Addressable Beam Smoke Detector with Two Way Communication | ||
1 | Application | For detection of Smoke | |
2 | Voltage range | 12 V/24VDC | |
3 | Protection Rang | 5- 100 mtr | |
4 | Adjustment angle | ±10 Degrees horizontal & vertical | |
5 | Sensitivity Levels | Level 1 – 25% Level 2 – 30% Level 3 – 40% Level 4 – 50% Acclimate™ Level 1 – 30 to 50% Acclimate Level 2 – 40 to 50% |
|
6 | Fault Conditions | 96% or more obscuration blockage In alignment mode Improper initial alignment Self-compensation limit reached |
|
7 | Alignment aid | Optical Gunsight | |
8 | Standby current | 450mA | |
9 | Operating frequency | 433.93 MHz. | |
10 | Ambient temperature range | -10deg C to +55deg C | |
111 | Wireless Protocol | Two Way Mesh /Multi-hop | |
12 | Inbuilt Transreceiver Two Way Communication Module | Mesh/Multi-hop RF Transceiver Module: Frequency bands 433.05 – 433.92MHz Number of channels 10 Data rate 1.2 - 100 Max output power 10 dBm Sensitivity -110 dBm Supply voltage 2.0 – 3.9 Volt Current consumption, RX / TX :24 / 35 mA Current consumption, SLEEP Typ. 0.3 uA Temperature range -40 to +85 Coding : Infinite Programmable at site Modulation :FSK Test Certificate : ERTL |
|
13 | Individual Data Transmission for |
|
|
14 | Wireless Protocol | Wireless MESH | |
15 | Point Read: Handshaking principle | A: Device status B: Device type C: Custom Device Label D: Software Zone Label E: Device Zone Assignments F: All Program Parameters. |
|
16 | Handshaking | The Detector shall be in handshaking mode with the respective Hooter panel, Local Monitoring station. Handshaking for health condition to be communicated to the Hooter panel & Local CMS via two way communication with MESH protocol.
Health condition monitoring in each 01 hrx24 hrs of Local Monitoring Station/ Local Hooter Panel so that different Audio visual alarm with graphic presentation of Health condition monitoring of all the devices in Wireless FDA system install in Plant area in fixed intervals. Low Bat, Detector Tamper sshall be communicated using wireless two way communication MESH protocol to the local hooter panel /Local CMS |
Wireless Addressable Gas Detector with Two Way Communication
A | Detector | Wireless Addressable Gas Detector with Two Way Communication |
1 | Application | For detection of Gas and Heat |
2 | Voltage range | 3.6 V/ 9VDC(Lithium battery) |
3 | Life of the battery | Minimum 7 years |
4 | Standby current | 20-30μA |
5 | Gas Detection | LPG / LNG |
6 | Setting | Resettable DIP Switch |
7 | Diiff. Alarm Output | Different alarm output |
8 | Operating frequency | 433.93 MHz. |
9 | Ambient temperature range | -10deg C to +55deg C |
10 | Wireless Protocol | Two Way Mesh /Multi-hop |
11 | Inbuilt Transreceiver Two Way Communication Module | Mesh/Multi-hop RF Transceiver Module:
Frequency bands 433.05 – 433.92MHz |
12 | Individual Data Transmission for |
|
13 | Wireless Protocol | Wireless MESH |
14 | Coverage Area | 25 sq.mtr |
15 | Point Read:Handshaking principle | A: Device status B: Device type C: Custom Device Label D: Software Zone Label E: Device Zone Assignments F: All Program Parameters. |
16 | Handshaking | The Detector shall be in handshaking mode with the respective Hooter panel , Local Monitoring station . Handshaking for health condition to be communicated to the Hooter panel & Local CMS via two way communication with MESH protocol.
Health condition monitoring in each 01 hrx24 hrs of Local Monitoring Station/ Local Hooter Panel so that different Audio visual alarm with graphic presentation of Health condition monitoring of all the devices in Wireless FDA system install in Plant area in fixed intervals. |
Wireless Addressable Manual Pull Station with Two Way Communication
H | MCP | Wireless Addressable Manual Pull Station with Two Way Communication |
1 | Application | For Manual Call Point |
2 | Voltage range | 3.6 V/ 9VDC(Lithium battery) |
3 | Life of the battery | Minimum 7 years |
4 | Standby current | 20-30μA |
8 | Operating frequency | 433.93 MHz. |
9 | Ambient temperature range | -10deg C to +55deg C |
10 | Wireless Protocol | Two Way Mesh /Multi-hop |
11 | Inbuilt Transreceiver Two Way Communication Module | Mesh/Multi-hop RF Transceiver Module: Frequency bands 433.05 – 433.92MHz Number of channels 17 Data rate 1.2 - 100 Max output power 10 dBm Sensitivity -110 dBm Supply voltage 2.0 – 3.9 Volt Current consumption, RX / TX :24 / 35 mA Current consumption, SLEEP Typ. 0.3 uA Temperature range -40 to +85 Coding : Infinite Programmable at site Modulation :FSK Test Certificate : ERTL |
12 | Individual Data Transmission for |
|
13 | Wireless Protocol | Wireless MESH |
14 | Point Read: Handshaking principle | A: Device status B: Device type C: Custom Device Label D: Software Zone Label E: Device Zone Assignments F: All Program Parameters. |
15 | Handshaking | The MCP shall be in handshaking mode with the respective Hooter panel , Local Monitoring station . Handshaking for health condition to be communicated to the Hooter panel & Local CMS via two way communication with MESH protocol.
Health condition monitoring in each 01 hrx24 hrs of Local Monitoring Station/ Local Hooter Panel so that different Audio visual alarm with graphic presentation of Health condition monitoring of all the devices in Wireless FDA system install in Plant area in fixed intervals. |
Wireless Fire Alarm Panel with Two Way Communication
A | Local Hooter Control Panel | Wireless Fire Alarm Panel with Two Way Communication |
1 | Application | Receiving & Transmitting signals to /from field and CMS |
2 | Voltage range | 230vAC/12vDC |
3 | Graphic display with Touch screen | 320x240 , 5.7” with Touch screen Controller |
4 | Standby current | 50-150mA |
5 | Addressable Loop | 04 Expandable |
6 | Event Recorder | 24 Events |
7 | Printer | Inbuilt Thermal Printer |
8 | Hooter | 110Db |
9 | Password protection | Touch screen |
10 | Data Entry | Through Touch Screen on graphic Display |
11 | Battery Back up | 12Vdc, 7.2AH with Auto Charger having Short Ckt, Over Voltage & Deep Discharge Protection |
12 | Mains Supply Fail | Transmit the Mains Fail Signal to CMS through inbuilt Transmitter |
13 | Mains Supply Indicator | LED , industrial Grade |
14 | Interface | RS232/485 |
15 | Operating frequency | 433.93 MHz. |
16 | Ambient temperature range | -10deg C to +55deg C |
17 | Wireless Protocol | Two Way Mesh /Multi-hop |
18 | Inbuilt Transreceiver Two Way Communication Module | Mesh/Multi-hop RF Transceiver Module: Frequency bands 433.05 – 433.92MHz Number of channels 17 Data rate 1.2 - 100 Max output power 10 dBm Sensitivity -110 dBm Supply voltage 2.0 – 3.9 Volt Current consumption, RX / TX :24 / 35 mA Current consumption, SLEEP Typ. 0.3 uA Temperature range -40 to +85 Coding : Infinite Programmable at site Modulation :FSK Test Certificate : ERTL |
19 | Individual Data Transmission to CMS For |
|
20 | Wireless Protocol | Wireless MESH |
21 | Point Read: Handshaking principle | A: Device status B: Device type C: Custom Device Label D: Software Zone Label E: Device Zone Assignments F: All Program Parameters. |
22 | Handshaking | The Hooter Control Panel HCP shall be in handshaking mode with the respective Local Monitoring station & CMS . Handshaking for health condition to be communicated to the Local CMS via two way communication with MESH protocol.
Health condition monitoring in each 01 hrx24 hrs to be communicated to Local Monitoring Station so that different Audio visual alarm with graphic presentation of Health condition monitoring of all the devices in Wireless FDA system install in Plant area in fixed intervals. |
Wireless Addressable Software based Voice Evacuation System
Wireless Addressable Software based Voice Evacuation System. | ||
A | HARDWARE | IBM/HP Tower Server for 24 x7 application |
2 | Application | For Voice Evacuation System |
3 | Processor | Intel® Xeon® Quad Core |
4 | Memory | 2GB standard memory |
5 | Cache | 8 MB |
6 | Hard Drive | 250GBX2 |
7 | Chipset | Intel compatible Chipset |
9 | RAID controller | RAID 1 |
10 | Disk bays Hot Swap |
Up to 2 nos 3.5" hot-swappable Serial Attached SAS |
11 | Network Interface | integrated dual Gigabit Ethernet |
12 | Industry standard compliance | Microsoft® Logo certifications
Operating System : Windows Server 2011 |
13 | Ports | Front: 2 USB Rear: 2 USB, 1 Ethernet, 1 video, 1 serial, |
14 | Power supply | Redundant Hot Swappable with external additional power supply |
15 | Server power cords | IEC power cord with NEMA power cord |
16 | System fans | 1 fan |
17 | Monitor | 21” LED. |
18 | UPS | 1 KVA |
19 | Server Rack | Standard |
20 | Printer | Laser Jet, Make -HP |
21 | Operating System | Microsoft Window 2011OEM with 5 user |
22 | Ethernet Switch | 8 port 10/100 MBPS |
B | Loop | 08 Loop |
D | IP Audio Zones | 8 Zone |
E | IP Amplifier | 1X100W 4 Ohm Mono channel Class D Amplifier |
g | Converter | 8x4 ohm 100w mono channel to 100 volt audio line Converter |
H | Interface | With Wireless Addressable Fire Detection System CMS |
I | IP Audio Decoder | Applications:
Features:
Technical Specifications: Electrical
Ethernet
Multicast capable
Analog Output
Audio formats
Discrete I/O
RS-232 Interface
Display
IR Interface
|
J | Speakers | 6W 100V Wall Mounted |
Wireless Addressable Relay Panel with Two Way Communication
A | Relay Control Panel | Wireless Addressable Relay Panel with Two Way Communication |
1 | Application | 3rd Party Integration |
2 | Voltage range | 230vAC/12vDC |
3 | Graphic display with Touch screen | 320x240 , 5.7” with Touch screen Controller |
4 | Standby current | 50-150mA |
5 | Addressable Loop | 04 Expandable |
6 | Event Recorder | 24 Events |
7 | Relay Contacts | 32 |
8 | Hooter | 110Db |
9 | Password protection | Touch screen |
10 | Data Entry | Through Touch Screen on graphic Display |
11 | Battery Back up | 12Vdc, 7.2AH with Auto Charger having Short Ckt, Over Voltage & Deep Discharge Protection |
12 | Mains Supply Fail | Transmit the Mains Fail Signal to CMS through inbuilt Transmitter |
13 | Mains Supply Indicator | LED , industrial Grade |
14 | Interface | RS232/485 |
15 | Operating frequency | 433.93 MHz. |
16 | Ambient temperature range | -10deg C to +55deg C |
17 | Wireless Protocol | Two Way Mesh /Multi-hop |
18 | Inbuilt Transreceiver Two Way Communication Module | Mesh/Multi-hop RF Transceiver Module: Frequency bands 433.05 – 433.92MHz Number of channels 17 Data rate 1.2 - 100 Max output power 10 dBm Sensitivity -110 dBm Supply voltage 2.0 – 3.9 Volt Current consumption, RX / TX :24 / 35 mA Current consumption, SLEEP Typ. 0.3 uA Temperature range -40 to +85 Coding : Infinite Programmable at site Modulation :FSK Test Certificate : ERTL |
19 | Individual Data Transmission to CMS For |
|
20 | Wireless Protocol | Wireless MESH |
21 | Point Read: Handshaking principle | A: Device status B: Device type C: Custom Device Label D: Software Zone Label E: Device Zone Assignments F: All Program Parameters. |
22 | Handshaking | The Hooter Control Panel HCP shall be in handshaking mode with the respective Local Monitoring station & CMS . Handshaking for health condition to be communicated to the Local CMS via two way communication with MESH protocol.
Health condition monitoring in each 01 hrx24 hrs to be communicated to Local Monitoring Station so that different Audio visual alarm with graphic presentation of Health condition monitoring of all the devices in Wireless FDA system install in Plant area in fixed intervals. |
Wireless PIR Motion Detector
- Bi-directional: The wireless detector gets receiver acknowledgement for each transmission.
- Adjust the detector’s features from anywhere by your smartphone.
- Option to program all detectors’ features by GSM adapter.
- Anti-masking protection.
- Two PIR sensors.
- Waterproof and all weather resistance.
- Shutters behind the lens allow limiting the PIR sensors vertical field of view.
- 2 provided plates allow installing the detector with a vertical tilt of 50 by each plate (100 by using both plates).
- Multi-directional Mounting BRACKET (Option).
Battery 3.6V, 1/2AA Lithium Battery Current Standby = 10μA, Max. Detection range Indoors = 12 meter
Outdoors = 8 meter
Wireless Addressable Software Based Control Command Center
Wireless Addressable Software Based Control Command Center | ||
A | HARDWARE | IBM/HP High End Rack Server for 24 x7 application |
2 | Application | For wireless FDA Plant Centralised Monitoring Station |
3 | Processor | Intel® Xeon® DUAL |
4 | Memory | 8GB standard memory |
5 | Cache | 2x6 MB |
6 | Hard Drive | 250GBX2 |
7 | Chipset | Intel compatible Chipset |
9 | RAID controller | RAID 1 |
10 | Disk bays Hot Swap | Up to 2 nos 3.5" hot-swappable Serial Attached SAS |
11 | Network Interface | integrated dual Gigabit Ethernet |
12 | Industry standard compliance | Microsoft® Logo certifications Operating System : Windows Server 2011 |
13 | Ports | Front: 2 USB Rear: 4 USB, 2 Ethernet, 1 video, 1 serial |
14 | Power supply | Redundant Hot Swappable with external additional power supply |
15 | Server power cords | IEC power cord with NEMA power cord |
16 | System fans | 2 fan |
17 | Monitor | ’32”x4 Video Wall. |
18 | UPS | 5 KVA , |
19 | Server Rack | Standard |
20 | Printer | Laser Jet, Make -HP |
21 | Operating System | Microsoft Window 2003 OEM with 5 user |
22 | Ethernet Switch | 8 port 10/100 MBPS |
B | Loop | 255 Loop, each Loop = 255 Devices |
C | 255 Loop Wireless Addressable Long Range RF Transreceiver with MESH protocol Two Way Communication | Specifications:
(3.0V, 25°C) Min Typ Max Unit |
D | Wireless Protocol | MESH |
IP Audio Decoder | Applications:
Features:
Technical Specifications: Electrical
Ethernet
Multicast capable
Analog Output
Audio formats
Discrete I/O
RS-232 Interface
Display
IR Interface
|
|
Communication & announcer unit |
|
|
E | Hooter | 110dbx4 |
G | Wireless Third Party Integration | MVWS, Innergen, Ventilation, Air conditioning , HVWS, Suppression system etc |
H | Auto Dialer | Tone based 20 nos Auto Dialer |
I | Transponder |
|
J | Wireless Range | 5km |
A. Video Wall: 32”4x4
Poroposed LCD Video wall should be a matrix of 4x4 NSL LCD or similar Display System having Four Nominal WXGA+ Modules stacked in TWO rows and TWO columns.
The Display controller to drive these NSL LCD Video wall should be Modules is kept below the mechanical structure of the Display Wall and the connecting cables between the Display Controller & LCD Modules run internally. The proposed solution of LCD Video wall will behave as a Single Logical Display with the help of our Display Controller. Display Controller will be running on WINDOWS XP professional operating system and would be connected to the Operator Workstations in the Control Room thru the Ethernet (10/100/1000 Mbps).
One can always load / install various WIN based applications on the Display Controller and can run them from there to show the display of the same on the Large Screen Display.
Display Controller can also take various inputs e.g. DVI, RGB, s-video. There should be a provision for 2 nos of DVI input in the proposed solution of streaming video inputs via quad streaming video input card.
One can also show the mirror images of the monitors of the WIN XP based OWS / PC connected with Display Controller over LAN. There should be provision of control room management software which will be seamlessly integrated with Wireless FDA systems. It will enable to show detail content on the LCD display wall.
Using the Software, one can always pre configure various display layouts to be displayed any time with a simple mouse click. The applications defined in a particular layout are automatically opened, sized and positioned accordingly on the LCD Display as soon as that particular layout is launched. There should be a provision for a provision for 6 clients to be added which are available on the same network for displaying the video content on LCD video wall. All clients should be IP based and on the same network.
Using the Remote Pointer functionality of software, the control of the keyboard and mouse of the Display Controller, can be taken over by any WINDOWS XP OWS’s keyboard and mouse if the same is connected with Display Controller over the LAN.
Features:
- Narrow-bezel LCD NSL Or similar display with WXGA (1366x768) resolution.
- Overall Gap between two LCD panels should be less than 7.3 to 10 mm .
- Size of 4X4 matrix of LCD wall
- Allows multiple sources in Native resolution without loss of pixel or scaling for control room applications.
- Multiple sources (video, PC content or streaming video) can be presented and positioned anywhere across the entire LCD stack.
- Accurate Color calibration for display consistency management to ensure correct white point and accurate grayscales.
- Front access removal of any LCD without removal of other LCD's.
- A special cooling concept to avoid heat spill over between LCD's
- Low noise.
- Can be serviced from the front and the back.
- Require no back room space at all, so they are ideally suited for control rooms where space is limited.
- No permanent burn in for use under 20 hours/day
- Anti Image Retention